LPV-120W Series LED Constant Voltage Waterproof Switching Power Supply

LPV-120W Series LED Constant Voltage Waterproof Switching Power Supply
LPV-120W Series LED Constant Voltage Waterproof Switching Power Supply

Features:

  • Constant voltage style power supply
  • 180~264VAC AC input range range
  • Small volume,low weight,high efficiency
  • Protections: short circuit/over load/over voltage/over temp
  • Cooling by free air convection
  • Fully encapsulated with IP67 level
  • 100% full load burn-in test
  • 2 Years warranty

Model

LPV-120-12

LPV-120-24

LPV-120-36

LPV-120-48

output

DC voltage

12V

24V

36V

48V

Voltage tolerance

±1%

±1%

±1%

±1%

Rated current

10A

5A

3.3A

2.5A

Current range

0~10A

0~5A

0~3.3A

0~2.5A

Rated power

120W

120W

118.8W

120W

Ripple&noise

100mvp-p

150mvp-p

150mvp-p

180mvp-p

input

Voltage range

180~264VAC,255~373VDC

Frequency

47~63HZ

AC current

1.2A/230VAC

Efficiency

82%

84%

84%

85%

Inrush current

Cold start current40A/230VAC

Leakage current

<2.5mA/240VAC

protection

Over load

Rated output power105%~135%start over load protection

Protection type: hiccup mode,auto-recovery after fault condition is removed

Over voltage

15.6~17.8V

30.6~33.2V

42.6~44.2V

54.8~56.6V

Protection type: hiccup mode,auto-recovery after fault condition is removed

Over temperature

Shell temp≥85℃,start over temperature protection

Protection mode: cutoff output,auto-recovery after temperature become normal

environment

Working temp,humidity

-10℃~+60℃,20%~90%RH

Storage temp.humidity

-20℃~+85℃,10%~95%RH non condensing

Withstand vibration

10~500HZ,2G10min/1cycle,period for 60minutes,each axes

safety

Withstand voltage

I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC

Isolated resistance

I/P-O/P、I/P-FG、O/P-FG:100Mohms/500VDC

Fits

tandard

Safety standard

Fit UL1012,IP67 protect level

EMC standard

Fit EN55022,CLASSA

Others

Dimension

215*69*43mm(L*W*H)

Weight/packing

1.1kg/20pcs/23kg/0.03 m³/1.07CUFT

Note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

> Technical Information

> How to install a CARSPA 1000 Watt Power Inverter in an RV?

As a lover of RV life and long-distance travel, I'm always looking for ways to make my travels more comfortable and self-sufficient. In my opinion, RV life is not on...

> Can 12V DC Power Inverter be used on trucks?

In modern truck life, the demand for electricity is increasing day by day. Truck drivers need to power not only basic devices, such as laptops and cell phones, but a...

> How to safely connect a battery to a 1000 watt power inverter

In modern life, the stability and reliability of power supply are crucial for home and outdoor activities. Whether it is to deal with unexpected power outages or to ...

> 1000 Watt Power Inverter: How Many Batteries Do You Really Need

When discussing a solar system or power bank setup, a common and critical component is the inverter. In particular, 1000 watt power inverters are popular due to thei...

GET A QUOTE

Get in Touch

×